Features:
WP10 series generator sets, generating power in 150KW-300KW,WP10 series generator set with easy maintenance, excellent performance indicators, low fuel consumption, three high environmental adaptability, durable and other advantages in the field of generator set by the majority of customers respect and trust. Our generator sets sell well all over the world.
Our advantages
1, the generator set adopts Weichai diesel engine as the power, supporting well-known brand generator.
2, the unit power range is wide: 10~4300KW
3, low fuel consumption, low emissions, low noise
4, the unit has excellent performance, advanced technology, reliable work and easy maintenance
5, high voltage regulation precision, good dynamic performance, compact structure, long service life
6. Weichai's products are subjected to the "three high" experiments of high altitude, high temperature and high cold all year round, and have strong environmental adaptability
7, start quickly, and can quickly reach full power only a few seconds, emergency 1 minute with the expiration of full load (normal 5~30MIN) shutdown process is short, you can frequently start and stop.
8, maintenance operation is simple, fewer people, easy to maintain during backup
9, the construction of diesel generator set and the lowest comprehensive cost of power generation
Technical Parameters
Serial number | Item | Argument | ||||
1 | Model | WPG206*8 | WPG250*8 | WPG275*8 | WPG344*8 | WPG375*8 |
2 | Standby Rating kVA/kWe | 206/165 | 250/200 | 275/220 | 350/280 | 375/300 |
3 | Prime Rating kVA/kWe | 187.5/150 | / | 250/200 | 320/250 | / |
4 | Voltage V | 400/230 | ||||
5 | Frequency Hz | 50 | ||||
6 | Power Factor | 0.8 | ||||
7 | No. of Phases | 3 | ||||
8 | Fuel consumption@25%/ 50% / 75%(L/h)75%(L/h) | 12.36 / 21.13 / 29.57 | 14.81 / 25.08 / 36.03 | 15.69/ 27.04 / 39.27 | 19.28 / 34.10 / 49.61 | 20.34 / 37.04 / 53.85 |
9 | Fuel consumption@100% / 110%(L/h) | 38.79 / 42.50 | 47.57 / 52.44 | 52.18 / 57.45 | 66.09 /73.13 | 71.96 / 79.65 |
10 | Sound@1m(dB·(A)) | 开式≤109;静音式≤95 | ||||
11 | Ambient temp(℃) | -10~45 | ||||
12 | Gen-set regulation class | ISO 8528-5 G2 |
Typical Genset Dimensions | ||||||
Genset Mode | Prime Rating (kVA) | Length A(mm) | Width B(mm) | Height C(mm) | Wet Weight* (kg) | Standard Fuel tank Capacity (L) |
WPG206B8 | 200 | 2999 | 1170 | 1780 | 2210 | — |
WPG206F8 | 200 | 2999 | 1170 | 1920 | 2370 | 420 |
WPG206L8 | 200 | 3900 | 1350 | 2050 | 3090 | 460 |
WPG206B8 | 200 | 2999 | 1170 | 1780 | 2330 | — |
WPG206F8 | 200 | 2999 | 1170 | 1920 | 2490 | 420 |
WPG206L8 | 200 | 3900 | 1350 | 2050 | 3120 | 460 |
WPG275B8 | 250 | 2999 | 1170 | 1780 | 2350 | — |
WPG275F8 | 250 | 2999 | 1170 | 1920 | 2510 | 420 |
WPG275L8 | 250 | 3900 | 1350 | 2050 | 3220 | 460 |
WPG350B8 | 320 | 2999 | 1170 | 1780 | 2630 | — |
WPG350F8 | 320 | 2999 | 1170 | 1920 | 2790 | 420 |
WPG350L8 | 320 | 4200 | 1350 | 2050 | 3620 | 510 |
WPG350B8 | 320 | 2999 | 1170 | 1780 | 2770 | — |
WPG350F8 | 320 | 2999 | 1170 | 1920 | 2930 | 420 |
WPG350L8 | 320 | 4200 | 1350 | 2050 | 3760 | 510 |
Features:
WP10 series generator sets, generating power in 150KW-300KW,WP10 series generator set with easy maintenance, excellent performance indicators, low fuel consumption, three high environmental adaptability, durable and other advantages in the field of generator set by the majority of customers respect and trust. Our generator sets sell well all over the world.
Our advantages
1, the generator set adopts Weichai diesel engine as the power, supporting well-known brand generator.
2, the unit power range is wide: 10~4300KW
3, low fuel consumption, low emissions, low noise
4, the unit has excellent performance, advanced technology, reliable work and easy maintenance
5, high voltage regulation precision, good dynamic performance, compact structure, long service life
6. Weichai's products are subjected to the "three high" experiments of high altitude, high temperature and high cold all year round, and have strong environmental adaptability
7, start quickly, and can quickly reach full power only a few seconds, emergency 1 minute with the expiration of full load (normal 5~30MIN) shutdown process is short, you can frequently start and stop.
8, maintenance operation is simple, fewer people, easy to maintain during backup
9, the construction of diesel generator set and the lowest comprehensive cost of power generation
Technical Parameters
Serial number | Item | Argument | ||||
1 | Model | WPG206*8 | WPG250*8 | WPG275*8 | WPG344*8 | WPG375*8 |
2 | Standby Rating kVA/kWe | 206/165 | 250/200 | 275/220 | 350/280 | 375/300 |
3 | Prime Rating kVA/kWe | 187.5/150 | / | 250/200 | 320/250 | / |
4 | Voltage V | 400/230 | ||||
5 | Frequency Hz | 50 | ||||
6 | Power Factor | 0.8 | ||||
7 | No. of Phases | 3 | ||||
8 | Fuel consumption@25%/ 50% / 75%(L/h)75%(L/h) | 12.36 / 21.13 / 29.57 | 14.81 / 25.08 / 36.03 | 15.69/ 27.04 / 39.27 | 19.28 / 34.10 / 49.61 | 20.34 / 37.04 / 53.85 |
9 | Fuel consumption@100% / 110%(L/h) | 38.79 / 42.50 | 47.57 / 52.44 | 52.18 / 57.45 | 66.09 /73.13 | 71.96 / 79.65 |
10 | Sound@1m(dB·(A)) | 开式≤109;静音式≤95 | ||||
11 | Ambient temp(℃) | -10~45 | ||||
12 | Gen-set regulation class | ISO 8528-5 G2 |
Typical Genset Dimensions | ||||||
Genset Mode | Prime Rating (kVA) | Length A(mm) | Width B(mm) | Height C(mm) | Wet Weight* (kg) | Standard Fuel tank Capacity (L) |
WPG206B8 | 200 | 2999 | 1170 | 1780 | 2210 | — |
WPG206F8 | 200 | 2999 | 1170 | 1920 | 2370 | 420 |
WPG206L8 | 200 | 3900 | 1350 | 2050 | 3090 | 460 |
WPG206B8 | 200 | 2999 | 1170 | 1780 | 2330 | — |
WPG206F8 | 200 | 2999 | 1170 | 1920 | 2490 | 420 |
WPG206L8 | 200 | 3900 | 1350 | 2050 | 3120 | 460 |
WPG275B8 | 250 | 2999 | 1170 | 1780 | 2350 | — |
WPG275F8 | 250 | 2999 | 1170 | 1920 | 2510 | 420 |
WPG275L8 | 250 | 3900 | 1350 | 2050 | 3220 | 460 |
WPG350B8 | 320 | 2999 | 1170 | 1780 | 2630 | — |
WPG350F8 | 320 | 2999 | 1170 | 1920 | 2790 | 420 |
WPG350L8 | 320 | 4200 | 1350 | 2050 | 3620 | 510 |
WPG350B8 | 320 | 2999 | 1170 | 1780 | 2770 | — |
WPG350F8 | 320 | 2999 | 1170 | 1920 | 2930 | 420 |
WPG350L8 | 320 | 4200 | 1350 | 2050 | 3760 | 510 |